ICDcodes.org
FY2027

I20.81Angina pectoris with coronary microvascular dysfunction

Billable

Is I20.81 billable?

Yes — I20.81 is billable for FY2027. I20.81 is a valid, billable ICD-10-CM code at the highest level of specificity in its branch. I20.81 may be submitted for encounters from October 1, 2026 through September 30, 2027.

I20.81 at a glance

CodeI20.81
DescriptionAngina pectoris with coronary microvascular dysfunction
BillableYes
Code setICD-10-CM FY2027
Valid for encountersOctober 1, 2026 – September 30, 2027

Which MS-DRGs does I20.81 group to?

I20.81 sits in MDC 05 and helps define the logic of 1 MS-DRG (version 44, FY2027). Which one a stay actually groups to also depends on procedures and secondary diagnoses.

  • 311Angina Pectorismedical

How is I20.81 listed in the Alphabetic Index?

These are the routes through the Alphabetic Index that lead to I20.81. They show the wording a clinician may have documented, which often differs from the Tabular description.

  • Anginawithcoronary microvascular disease (attack) (cardiac) (chest) (heart) (pectoris) (syndrome) (vasomotor)
  • Anginawithcoronary microvascular dysfunction (attack) (cardiac) (chest) (heart) (pectoris) (syndrome) (vasomotor)
  • Dysfunctioncoronary microvascularwithangina pectoris
  • Disease, diseasedcoronarymicrovascularwithangina pectoris

Inclusion terms

Alternative wording in documentation that is classified to I20.81.

  • Angina pectoris with coronary microvascular disease

Excludes1 — never code together — inherited from I20

The conditions below can never be reported together with I20.81 on the same claim. An Excludes1 note means the two conditions cannot occur in the same patient, so reporting both is a coding error.

  • angina pectoris with atherosclerotic heart disease of native coronary arteries (I25.1-)
  • atherosclerosis of coronary artery bypass graft(s) and coronary artery of transplanted heart with angina pectoris (I25.7-)
  • postinfarction angina (I23.7)

Use additional code — inherited from I20

Report an additional code alongside I20.81 to fully describe the condition. I20.81 is sequenced first.

  • code to identify:
  • exposure to environmental tobacco smoke (Z77.22)
  • history of tobacco dependence (Z87.891)
  • occupational exposure to environmental tobacco smoke (Z57.31)
  • tobacco dependence (F17.-)
  • tobacco use (Z72.0)

Use additional code — inherited from I20.8

Report an additional code alongside I20.81 to fully describe the condition. I20.81 is sequenced first.

  • code(s) for symptoms associated with angina equivalent

Excludes2 — not included here — inherited from Chapter 9

The conditions below are not part of I20.81, but a patient may have both at the same time. When documentation supports it, I20.81 and the excluded code may both be reported.

  • certain conditions originating in the perinatal period (P04-P96)
  • certain infectious and parasitic diseases (A00-B99)
  • complications of pregnancy, childbirth and the puerperium (O00-O9A)
  • congenital malformations, deformations, and chromosomal abnormalities (Q00-Q99)
  • endocrine, nutritional and metabolic diseases (E00-E88)
  • injury, poisoning and certain other consequences of external causes (S00-T88)
  • neoplasms (C00-D49)
  • symptoms, signs and abnormal clinical and laboratory findings, not elsewhere classified (R00-R94)
  • systemic connective tissue disorders (M30-M36)
  • transient cerebral ischemic attacks and related syndromes (G45.-)

Code also — inherited from I20-I25

Two codes may be needed to describe the condition fully. Whether I20.81 is sequenced first depends on the reason for the encounter.

  • the presence of hypertension (I10-I1A)

How long has I20.81 existed?

I20.81 first appears in FY2024.

Derived from the official order files for FY2016–FY2026. FY2017 and FY2020 publish no order file, so those years are not covered.

Which conditions are coded to I20.81?

What other codes are in the I20.8 family? (1)