T85.121 — Displacement of implanted electronic neurostimulator of peripheral nerve electrode (lead)
Is T85.121 billable?
No — T85.121 is a non-billable header code. T85.121 groups more specific codes and cannot be submitted on a claim. A valid ICD-10-CM code must be reported at the highest level of specificity available in its branch. Select one of the 3 billable codes beneath T85.121.
Billable codes under this header
- T85.121ADisplacement of implanted electronic neurostimulator of peripheral nerve electrode (lead), initial encounter
- T85.121DDisplacement of implanted electronic neurostimulator of peripheral nerve electrode (lead), subsequent encounter
- T85.121SDisplacement of implanted electronic neurostimulator of peripheral nerve electrode (lead), sequela
T85.121 at a glance
| Code | T85.121 |
|---|---|
| Description | Displacement of implanted electronic neurostimulator of peripheral nerve electrode (lead) |
| Billable | No — header code |
| Code set | ICD-10-CM FY2027 |
| Valid for encounters | October 1, 2026 – September 30, 2027 |
How is T85.121 listed in the Alphabetic Index?
These are the routes through the Alphabetic Index that lead to T85.121. They show the wording a clinician may have documented, which often differs from the Tabular description.
- Complication › electronic stimulator device › peripheral nerve › mechanical › displacement (s) (from) (of)
- Complication › electronic stimulator device › peripheral nerve › mechanical › malposition (s) (from) (of)
Inclusion terms
Alternative wording in documentation that is classified to T85.121.
- Displacement of electrode (lead) for cranial nerve neurostimulators
- Displacement of electrode (lead) for gastric neurostimulator
- Displacement of electrode (lead) for sacral nerve neurostimulator
- Displacement of electrode (lead) for vagal nerve neurostimulators
Use additional code — inherited from Chapter 19
Report an additional code alongside T85.121 to fully describe the condition. T85.121 is sequenced first.
- code to identify any retained foreign body, if applicable (Z18.-)
Use additional code — inherited from T80-T88
Report an additional code alongside T85.121 to fully describe the condition. T85.121 is sequenced first.
Excludes2 — not included here — inherited from Chapter 19
The conditions below are not part of T85.121, but a patient may have both at the same time. When documentation supports it, T85.121 and the excluded code may both be reported.
Excludes2 — not included here — inherited from T80-T88
The conditions below are not part of T85.121, but a patient may have both at the same time. When documentation supports it, T85.121 and the excluded code may both be reported.
- any encounters with medical care for postprocedural conditions in which no complications are present, such as:
- artificial opening status (Z93.-)
- closure of external stoma (Z43.-)
- fitting and adjustment of external prosthetic device (Z44.-)
- burns and corrosions from local applications and irradiation (T20-T32)
- complications of surgical procedures during pregnancy, childbirth and the puerperium (O00-O9A)
- mechanical complication of respirator [ventilator] (J95.850)
- poisoning and toxic effects of drugs and chemicals (T36-T65 with fifth or sixth character 1-4 or 6)
- postprocedural fever (R50.82)
- specified complications classified elsewhere, such as:
- cerebrospinal fluid leak from spinal puncture (G97.0)
- colostomy malfunction (K94.0-)
- disorders of fluid and electrolyte imbalance (E86-E87)
- functional disturbances following cardiac surgery (I97.0-I97.1)
- intraoperative and postprocedural complications of specified body systems (D78.-, E36.-, E89.-, G97.3-, G97.4, H59.3-, H59.-, H95.2-, H95.3, I97.4-, I97.5, J95.6-, J95.7, K91.6-, L76.-, M96.-, N99.-)
- ostomy complications (J95.0-, K94.-, N99.5-)
- postgastric surgery syndromes (K91.1)
- postlaminectomy syndrome NEC (M96.1)
- postmastectomy lymphedema syndrome (I97.2)
- postsurgical blind-loop syndrome (K91.2)
- ventilator associated pneumonia (J95.851)
Excludes2 — not included here — inherited from T85
The conditions below are not part of T85.121, but a patient may have both at the same time. When documentation supports it, T85.121 and the excluded code may both be reported.
- failure and rejection of transplanted organs and tissue (T86.-)
What codes fall under T85.121? (3)
- T85.121ADisplacement of implanted electronic neurostimulator of peripheral nerve electrode (lead), initial encounter
- T85.121DDisplacement of implanted electronic neurostimulator of peripheral nerve electrode (lead), subsequent encounter
- T85.121SDisplacement of implanted electronic neurostimulator of peripheral nerve electrode (lead), sequela
How long has T85.121 existed?
T85.121 has been in ICD-10-CM since at least FY2016, the earliest fiscal year on record here.
- FY2018Displacement of implanted electronic neurostimulator (electrode) of peripheral nerveDisplacement of implanted electronic neurostimulator of peripheral nerve electrode (lead)
Derived from the official order files for FY2016–FY2026. FY2017 and FY2020 publish no order file, so those years are not covered.
What other codes are in the T85.12 family? (4)
- T85.120Displacement of implanted electronic neurostimulator of brain electrode (lead)not billable
- T85.122Displacement of implanted electronic neurostimulator of spinal cord electrode (lead)not billable
- T85.123Displacement of implanted electronic neurostimulator, generatornot billable
- T85.128Displacement of other implanted electronic stimulator of nervous systemnot billable